A manufacturer's name on a directory is a starting point for sourcing domestic-content solar modules. It is not proof that a particular model, consignment or serial number meets Domestic Content Requirement (DCR) rules. For a scheme project that requires DCR, choose the applicable module and cell specifications, ask for traceable documents, and verify the actual module or DCR certificate on the National Institute of Solar Energy (NISE) portal before committing it in a customer quotation.

Directory snapshot: 23 November 2026. The NISE DCR portal dashboard showed 147 solar module manufacturer entries when this list was extracted. The full directory appears below, with the names and states as shown by the portal. The count describes portal entries, not 147 independently certified DCR brands or 147 currently available products. The NISE certificate and panel lookup is the check that matters for a specific module. This distinction should appear in a sales team's procurement checklist, not as a small disclaimer after the price.

This guide is written for an Indian installer or EPC team preparing a solar proposal. It explains how to use the list, what the NISE portal can confirm, how DCR relates to the Approved List of Models and Manufacturers (ALMM), and how to write a quote without promising compliance that has not been checked. It does not rank manufacturers or recommend a supplier. Availability, models, warranty and price require fresh, model-specific evidence from each supplier.

What DCR means in a panel purchase

Domestic content is a supply-chain requirement for particular government-supported solar programmes. It concerns where the relevant solar cells and modules were manufactured, as defined by the applicable scheme and MNRE orders. A module assembled in India does not automatically satisfy a requirement for domestically manufactured cells. A familiar brand name, a local warehouse or an Indian invoice is not a replacement for cell-to-module traceability.

The NISE DCR Verification Portal describes a chain in which cell makers, module makers, resellers and EPCs register; manufacturing and sales data are uploaded; NISE verifies the chain; and a certificate can be issued for compliant modules. Its public verification page accepts a certificate number or panel serial number. A result can show a module as DCR or NDCR. NISE portal overview; public verification page. Read the actual result, including the module details and status, before carrying that claim into a proposal.

For an installer, DCR is therefore a property to establish for the specific supply being proposed, not a permanent adjective attached to a manufacturer. A company may produce different module types, use different input supply chains, or have stock that was registered through different routes. An old brochure for a model does not prove that the modules delivered for this project have the required domestic content. Nor does a portal registration make every future batch compliant.

DCR also should not be mistaken for a quality or performance rating. It says nothing by itself about annual yield, product workmanship, warranty service or the suitability of a module for a roof. Assess those questions with the model datasheet, applicable test certificates, warranty terms, installer design and procurement due diligence. A compliant module can still be the wrong dimension or electrical match for the project. A well-performing module can still be ineligible for a scheme that requires DCR.

When to check DCR before quoting

Start with the customer's actual programme and approval route. A residential customer seeking central financial assistance under PM Surya Ghar, a government procurement, and a private commercial buyer can face different conditions. Do not paste a DCR line from one proposal into another. Ask which scheme, tender or utility process applies; obtain its current documents; record the rule date; and write the compliance scope into the quote. The MNRE rooftop programme page and the relevant scheme portal are the starting points for scheme-specific conditions.

If DCR is mandatory, identify it before requesting supplier prices. A supplier may offer a lower-cost alternative that is not eligible for the selected scheme. Comparing that price with a DCR option without labeling the difference misleads the customer. Conversely, do not add a DCR premium to a private project as a supposed legal requirement unless its contract or applicable rule actually demands it. The customer's choice should be based on the project requirement, equipment and documented offer.

Use a procurement requirement such as: “Modules supplied under this option must have a verifiable DCR status for their serial numbers under the applicable scheme at dispatch and delivery.” The precise contractual wording needs review against the programme and purchase terms. The quotation can state that final model and serial numbers will be recorded on the delivery schedule, while the accepted price and substitution procedure remain clear. If the supplier cannot demonstrate a route to verification, do not describe that stock as confirmed DCR.

The 147 portal-listed solar module manufacturer entries

The table is a dated transcription of the solar module manufacturer roles in the public NISE dashboard. “Module only” and “Cell and module” are portal role labels, not a verdict on domestic content of an individual module. A state is the dashboard location, not a claim that all factories or shipments are in that state. Names are reproduced as displayed, including possible legal-name or spelling differences. A repeated name may represent more than one portal record. Search the current dashboard and verify the actual certificate or panel serial number before placing an order.

Manufacturer name as shown on NISE dashboardStatePortal role
Aatmanirbar Solar Private LimitedGujaratModule only
Abhishek Solar Industries Private LimitedJharkhandModule only
Adani New Industries LimitedGujaratModule only
ADM Solar Power And Infrastructure Private LimitedHaryanaModule only
Aelius Turbina LlpMaharashtraModule only
AG Solar Urja UdyogOdishaModule only
Agrawal Renewable Energy Private LimitedGoaModule only
Akshaya Solar Power (India) Private LimitedTelanganaModule only
Alpex Solar LimitedUttar PradeshModule only
Amrut Energy Private LimitedGujaratModule only
Ankur Traders & Engineers Private LimitedUttar PradeshModule only
Arkalight Solar Private LimitedGujaratModule only
Army Solar Energy Private LimitedGujaratModule only
Asote Solutions Private LimitedGujaratModule only
Atal Solar Private LimitedGujaratModule only
Australian Premium Solar (India) LimitedGujaratModule only
Avaada Electro LimitedUttar PradeshCell and module
Avco Power Private LimitedGujaratModule only
Axitec Energy India Private LimitedDelhiModule only
Bluebird Solar Private LimitedDelhiModule only
BVG India LimitedUttar PradeshModule only
Citizen Solar Private LimitedGujaratModule only
CONTENDRE GREENERGY LIMITEDMaharashtraModule only
COSMIC PV Power LimitedGujaratModule only
Credence Solar Panels Private LimitedGujaratModule only
CRK Renewable EnergiesKarnatakaModule only
Eastman Green Technologies Private LimitedHaryanaModule only
Easy Photo Voltech Private LimitedUttar PradeshModule only
ECE India Energies Private LimitedMaharashtraModule only
Emmvee Photovoltaic Power LimitedKarnatakaModule only
Emmvee Energy Private LimitedKarnatakaCell and module
FS Green Energies Private LimitedGujaratModule only
FS India Solar Ventures Private LimitedTamil NaduCell and module
Fujiyama Power Systems LimitedUttar PradeshCell and module
Ganesh Green Bharat LimitedGujaratModule only
Gautam Solar Private LimitedUttarakhandModule only
Goldi Solar Private LimitedGujaratModule only
Goldi Sun Private LimitedGujaratModule only
Green Brilliance Renewable Energy LLPGujaratModule only
Green Valley MotorsWest BengalModule only
Grew Energy Private LimitedRajasthanCell and module
H.Q Lamps Manufacturing Co Private LimitedHaryanaModule only
Havells India LimitedUttar PradeshModule only
Hexatron Industries LimitedGujaratModule only
Himalayan Solar LimitedHaryanaModule only
HR Solar Solution Private LimitedWest BengalModule only
Icon Solar-En Power Technologies Private LimitedChhattisgarhModule only
Indosolar LimitedUttar PradeshModule only
Insolation Energy LimitedRajasthanModule only
Insolation Green Energy Private LimitedRajasthanModule only
Integrated Batteries India Private Limited (Ib Solar)DelhiModule only
Inter Solar Systems Private LimitedPunjabModule only
Ish Solar Private LimitedGujaratModule only
Jakson Engineers LimitedUttar PradeshModule only
Jeem Energy Private LimitedGujaratModule only
Junna Solar Systems LimitedTelanganaModule only
KLK Ventures Private LimitedUttar PradeshModule only
Knack Energy Private LimitedGujaratModule only
Kosol Energie Private LimitedGujaratModule only
Laxmi Solar Power System Private LimitedChhattisgarhModule only
Loom Solar Private LimitedHaryanaModule only
Lubi ElectronicsGujaratModule only
Luminous Power Technologies Private LimitedUttarakhandModule only
M/s. Sun 2 Earth SolarGujaratModule only
Macwin Solar Energy Private LimitedGujaratModule only
Matri Shree Green Private LimitedUttar PradeshModule only
MKTEK Solpower India Private LimitedHaryanaModule only
MULTI INFRASTRUCTURE & ENGINEERING PRIVATE LIMITEDHaryanaModule only
Mundra Solar Energy LimitedGujaratCell and module
Mundra Solar PV LimitedGujaratCell and module
Nav-Yug Solar LLPGujaratModule only
Navitas Green Solutions Private LimitedGujaratModule only
Navitas Solar Private LimitedGujaratModule only
Nelson Surface LlpGujaratModule only
Nexgenix Solar Manufacturing Private LimitedGujaratModule only
Nextbrio Industries Private LimitedUttar PradeshModule only
Nithin Sai Renewables Private LimitedKarnatakaModule only
Northgreen Energy Private LimitedGujaratModule only
Novasys Greenergy LimitedMaharashtraModule only
Nrg Sol Power Private LimitedChhattisgarhModule only
ORB Energy Private LimitedKarnatakaModule only
Oswal Solar Energy Private LimitedHaryanaModule only
Padmapat EnergyRajasthanModule only
Pahal Solar Private LimitedGujaratModule only
Pixon Green Energy Private LimitedGujaratModule only
Poola Energy Private LimitedAndhra PradeshModule only
Powertrac Solar Projects LimitedGujaratModule only
Pravanya Solar India Private LimitedUttarakhandModule only
Premier Energies Global Environment Private LimitedTelanganaModule only
Premier Energies International Private LimitedTelanganaCell and module
Premier Energies Photovoltaic Private LimitedTelanganaCell and module
PV Power Technologies Private LimitedMaharashtraModule only
Raajratna Ventures LimitedGujaratModule only
Radiant green Energy Private LimitedAndhra PradeshModule only
Rajasthan Electronics And Instruments LimitedRajasthanModule only
Rajdeep Solar Energy Private LimitedGujaratModule only
Rayon Illumination Solar Solution Private LimitedMaharashtraModule only
Rayzon Solar LimitedGujaratModule only
Redren Energy Private LimitedGujaratModule only
Reliance Industries LimitedGujaratCell and module
Renew Photovoltaics Private LimitedHaryanaCell and module
Renewsys India Private LimitedMaharashtraCell and module
Rhine Solar LimitedHaryanaModule only
RPSG Solvanta Private LimtedRajasthanModule only
Saatvik Green Energy Private LimitedHaryanaModule only
Saatvik Solar Industries Private LimitedHaryanaModule only
Sael Solar Manufacturing Private LimitedPunjabModule only
Sael Solar P6 Private LimitedRajasthanModule only
Sahaj Solar LimitedGujaratModule only
Sahjanand Green Energy LLPGujaratModule only
Sangam Solar One Private LimitedGujaratModule only
Sasa Energy LLPGujaratModule only
Satyam EnterprisesUttar PradeshModule only
Satyam EnterprisesUttar PradeshModule only
Senses 14 Power Solution LlpBiharModule only
Silver Consumer Electricals LimitedGujaratModule only
Sirius Solar Energy Systems Private LimitedTelanganaModule only
SKKYTOP POWER LIMITEDGujaratModule only
Slr Solar Private limitedRajasthanModule only
Solarium Green Energy LimitedGujaratModule only
Solarmint Energies Private LimitedHaryanaModule only
Solberry Energy Private LimitedGujaratModule only
Solex Energy LimitedGujaratModule only
Solitech Green Energy Private LimitedGujaratModule only
Sova Solar LimitedWest BengalModule only
Spark Solar Technologies Private LimitedMaharashtraModule only
Sri Savitr Solar Private LimitedTelanganaModule only
SSSV Textile IndustriesHaryanaModule only
Sudarshan Saur Shakti Private LimitedMaharashtraModule only
Sunbond Energy Private LimitedGujaratModule only
Sunify Solar LLPGujaratModule only
Surana Solar LimitedTelanganaModule only
Surya International Enterprise Private LimitedOdishaModule only
Swelect HHV Solar Photovoltaics Private LimitedTamil NaduModule only
Tata Power Renewable Energy LimitedKarnatakaCell and module
Total Solar Technologies Private LimitedGujaratModule only
TP Solar LimitedTamil NaduCell and module
Unique Sun Power Private LimitedGujaratModule only
Uratom Solar (India) Private LimitedGujaratModule only
Veda Solar Private LimitedGujaratModule only
Vikram Solar LimitedWest BengalModule only
Visaka Industries LimitedTelanganaModule only
VSL Green Power Private LimitedTamil NaduModule only
Vsole Power Private LimitedGujaratModule only
Waaree Energies LimitedMaharashtraCell and module
Websol Energy System LimitedWest BengalCell and module
Worldone Energies Private LimitedMaharashtraModule only

Source and scope: NISE DCR portal public dashboard, accessed 23 November 2026. The 147 rows are portal records for “Solar-Panels Manufacturer Only” and “Both Solar-Cells and Solar-Panels Manufacturer.” The live dashboard can change. The list does not establish current stock, ALMM eligibility for a named model, DCR certification for a batch, price or quality.

Why a directory entry is not a DCR certificate

The public directory is useful because it narrows a search to organisations registered in module-manufacturer roles. Its limitation is equally important: it is a list of organisations, while procurement needs evidence about exact modules. A company can appear in the directory before you have a certificate number for your consignment. A distributor may supply a brand whose label is familiar but whose specific panels are not yet matched to the project's documentation. The buyer needs an audit trail from order to handover.

The NISE portal's own explanation separates registration, data upload, verification and certificate issue into steps. That separation is a useful control for the sales process. Do not write “NISE-certified manufacturer” solely because the dashboard displays the manufacturer. Request the portal-verifiable certificate and the serial-number schedule. If the purchase is placed before serial numbers are allocated, state the evidence that will be supplied before dispatch and the remedy if verification fails. NISE portal process.

A screenshot of a successful search should include the date and the visible result, but keep the original certificate or portal reference as well. Screenshots can be cropped or become stale. The verification itself should be performed against the live NISE lookup, with the number typed from the delivered document or panel label. Match the returned details against the purchase order, invoice, packaging and panel label. If the portal result is missing or inconsistent, ask the supplier to resolve the discrepancy before installation or scheme submission.

DCR and ALMM answer different questions

ALMM is MNRE's Approved List of Models and Manufacturers framework. List-I concerns solar PV modules; List-II concerns cells. DCR addresses domestic manufacturing requirements for an applicable scheme. These checks interact, but one does not silently replace the other. A name in a module-maker directory is not the same as an approved model entry; an approved model entry does not establish that every delivered module has a DCR-compliant cell chain.

Use the current official ALMM documents when the programme requires them. The MNRE ALMM information page and the NISE portal's ALMM links point to the official lists. The applicable date and transition rule can affect a project. A historic PDF in a sales folder may be superseded; a draft list is not the same as an effective list. Record the revision date beside the model you propose.

A practical quotation file can have three columns: proposed module model and rating; applicable ALMM entry and list revision; DCR verification evidence or the stated delivery-stage verification condition. Add the cell model or cell supplier evidence where the scheme and portal workflow call for it. This does not turn the quote into a technical certification. It makes the claim traceable and gives procurement a way to stop a substitution that would invalidate the project.

CheckDocument or lookup to requestWhat it establishesWhat it does not establish
Manufacturer roleCurrent NISE dashboard entryOrganisation appears in a portal roleEvery product is DCR-compliant
ALMM modelCurrent official list and exact model matchListed status within that list's scope and dateDCR status of delivered serial numbers
DCR certificate or panel lookupLive NISE verification resultStatus shown for that certificate or panelWarranty, yield or price
Commercial supplySupplier quotation, purchase order and invoiceModel, quantity, price and delivery obligationsScheme compliance without matching evidence
Delivery inspectionLabel/serial-number schedule and handover recordWhat was physically deliveredValidity of unverified declarations

The table is a workflow, not an assertion that one document always satisfies every programme. The scheme, tender and utility may ask for additional declarations or a particular upload format. Preserve the actual rules and supplier documents with the customer file.

Ask manufacturers and distributors the right questions

Start a supplier enquiry with the project facts: state and DISCOM, scheme or tender, AC/DC plant size, roof constraints, required module rating, delivery location and estimated date. Ask for an exact module model and current datasheet. A salesperson who receives only “price for DCR panels” may return a price for the wrong wattage, construction or supply chain. Get the full model designation, not only the brand and a nominal Wp number.

Ask the supplier which entity invoices you, where the panels will ship from, and what evidence will accompany them. If the supplier is a reseller, its role in the NISE traceability process matters. Request a sample certificate format, the portal verification method and a commitment to supply the serial-number schedule for the actual stock. Do not accept a sample certificate as proof for every panel in a future order. Ask how a replacement panel will be documented if one breaks during transport or commissioning.

Commercial terms deserve the same attention. Request a dated quote with quantity, unit price, GST treatment, freight, transit risk, lead time, warranty document, payment milestones and validity. Ask whether the price changes if the ordered model is substituted or if the project delivery date moves. Compare offers on the same module model class and delivery basis. A cheap ex-factory number and an expensive delivered-to-site number are not comparable until transport, tax and risk are aligned.

The manufacturer's warranty should be checked independently of the DCR certificate. Read the product and performance warranty documents, exclusions and claim process for the exact brand and model. Check who handles a failure in the customer's location and who pays removal, transport and reinstallation if those costs are excluded. Avoid a blanket “25-year warranty” phrase if the documents divide product and performance terms differently.

A procurement sequence that survives substitutions

  1. Name the rule. Save the current scheme or tender requirement and its date. Decide whether DCR, ALMM or both apply to this project.
  2. Fix the proposed equipment. Select a model from current technical evidence and confirm electrical and mechanical fit. Record the model designation and rated power.
  3. Request traceable supply. Ask the supplier for the current ALMM model evidence and the DCR portal path for the actual stock. Document any delivery-stage condition.
  4. Write the purchase order precisely. Include model, quantity, acceptance evidence, serial-number schedule, permitted substitutions and the consequence of failure to provide compliant goods.
  5. Check before installation. At receipt, compare packaging, labels, serial numbers, invoice and portal results. Quarantine discrepancies until they are resolved.
  6. Keep the handover trail. Save the accepted certificate/result, serial schedule, model sheet and invoice with the customer's system documents and scheme submission.

This sequence is useful even when the installer is not applying for a subsidy. It catches a common project problem: the equipment line in the sales proposal stays unchanged while procurement quietly buys a different model. That can alter string design, warranty, dimensions and approval documents. A documented substitution step protects both parties.

If the portal is unavailable at a critical time, record the attempted verification and seek the scheme authority or portal support's written direction. Do not convert an outage into an assumption that the panels are compliant. If a delivered panel returns an NDCR result when the project requires DCR, stop and resolve it with the supplier. A general manufacturer registration cannot override a contradictory panel-level status.

Show the customer a clear, conditional equipment line

A customer-facing quote should identify the module manufacturer, exact model, quantity, total DC capacity, construction or technology where relevant, applicable warranty document and the price basis. Where DCR is required, write the requirement and how it will be evidenced. A useful equipment note is: “DCR compliance for supplied modules will be evidenced by the NISE portal certificate or serial-number result and matched to the delivery schedule before installation.” Use only if the supplier has accepted that obligation and the scheme permits the timing.

Avoid promising an unrestricted brand swap. If a model becomes unavailable, offer a revised specification and obtain customer and scheme approval before purchasing. A substitute may have different dimensions, open-circuit voltage, temperature coefficient, connector, warranty or status on the applicable list. “Equivalent wattage” is not enough. The quote should make changes visible through a revised version with date and approval record.

Do not use the list above as a brand recommendation section in a sales PDF. It is a research directory for the installer. The buyer needs the proposed equipment and evidence relevant to their system. If you include alternative brands, give each one its own model, compliance status, supply condition and price. Do not create a false comparison by pairing a verified available model with an unverified name from the dashboard.

Quickest Solar CRM can put the selected product items, photos and terms into a branded proposal PDF and share it through WhatsApp. The quotation-system feature can make those choices readable to the customer. The app does not validate DCR or replace a live NISE lookup. Attach or reference the verified equipment evidence in your customer process, then start free to inspect the proposal layout.

Answers installers often need

Is every name in this list a DCR manufacturer? It is a registered module-manufacturer portal entry as of the snapshot date. That does not prove DCR status of every model or panel. Verify the actual certificate or serial number.

Can I quote any model from an ALMM-listed company? Check the exact model against the relevant current list and the programme's conditions. A company name alone is not a model match. If DCR is required, make the separate DCR check.

Can I rely on the supplier's “Made in India” brochure? Use it as a lead for further enquiry, not final compliance evidence. The applicable scheme defines what must be domestic and what evidence is accepted. The NISE portal provides the panel/certificate check for DCR.

What if the panel serial number is not available when the customer wants a quote? Name the proposed model and write the verification condition, timing and substitution remedy. Do not invent serial numbers or describe a future batch as already verified. Before buying and installing, check the actual stock.

What if the supplier changes the model after advance payment? Require a revised written equipment schedule, technical review and a fresh compliance check before acceptance. The purchase order should state how price, timing and refunds work if the replacement fails the project requirement.

The useful list is the one you can trace to a dated official source and then narrow to the actual delivered modules. Begin with this 23 November 2026 directory, check the current portal and official lists, and carry the evidence through the purchase order, quote and handover file. That is the basis for a defensible DCR claim.

Want to put this into practice?

Keep your solar leads, proposal documents and follow-up tasks in one workflow.

Create account

Get the next post in your inbox.

Get practical guides for solar sales and proposals. Unsubscribe anytime.