Solar DC cable has no single dependable price per metre. The figure depends on conductor size, cable construction and standard, manufacturer, purchase quantity, taxes, freight and the date of the supplier offer. For a customer quote, first specify the cable and calculate the installed route length. Then apply a current supplier price to the required purchased quantity, including both positive and negative runs, termination allowance and likely offcuts.
A dated public benchmark shows why “₹X per metre” needs a label. RR Kabel's price list effective 24 August 2026 lists its single-core solar DC cable at ₹15,317 per 100 metres for 4 mm² and ₹22,116 per 100 metres for 6 mm². That is ₹153.17/m and ₹221.16/m as list-rate arithmetic, before GST. The list says prices can change without notice, orders should use standard packing and freight follows its stated consignment terms. These are manufacturer list rates, not a promise that an installer can buy any length at those rates or that a customer should be charged those exact amounts. Check the current RR Kabel price-list page and obtain a dated supplier quotation before issuing a final proposal.
This guide is for Indian rooftop solar installers who need to turn a cable schedule into a transparent customer price. It gives sourced list-rate examples, a length calculation, a quote-line format and the checks that prevent a cheap-looking cable allowance from becoming a site variation. It does not prescribe a conductor size for any particular installation. A competent designer must select cable and protection for the actual current, voltage, installation method, temperature, route and applicable rules.
A dated price table you can audit
RR Kabel's August 2026 manufacturer list describes an annealed tinned copper, single-core, UV-resistant solar DC cable with crosslinked halogen-free insulation and sheath. It names IS 17293, EN 50618 and IEC 62930 in the product section. The published rates below are for 100 metres; the per-metre column is simple division by 100. GST is excluded by the list's terms. This is one manufacturer's published schedule, not a market average or an installed price. RR Kabel August 2026 price list, solar cable section and terms.
| Nominal conductor area | Manufacturer list rate per 100 m | Arithmetic list rate per metre | Listed standard packing indication |
|---|---|---|---|
| 2.5 mm² | ₹10,981 | ₹109.81/m | 100 or 200 m |
| 4 mm² | ₹15,317 | ₹153.17/m | 500, 1,000 or 2,000 m |
| 6 mm² | ₹22,116 | ₹221.16/m | 500, 1,000 or 2,000 m |
| 10 mm² | ₹38,621 | ₹386.21/m | 500 or 1,000 m |
| 16 mm² | ₹59,773 | ₹597.73/m | 500 or 1,000 m |
Scope: RR Kabel solar DC cable list effective 24 August 2026; manufacturer list rates exclude GST and may change without notice. The packing column is the list's stated coil information, not a claim that every buyer must buy a full coil. Confirm current supply, minimum order, colour, discount and delivery with the seller. Do not combine these values with a price for a different construction or brand and call it a like-for-like comparison.
A supplier's net selling price may be below or above the arithmetic list rate after discounts, distribution, logistics and tax. A purchaser who needs only 85 metres may receive a cut-length price or have to buy a full standard coil. The public list does not settle that transaction. It does give an auditable reference for the size and product family, and it lets an installer see the scale of the difference between 4 and 6 mm² before a design is fixed. The final cable line should still come from the supplier offer for the exact item and quantity.
If another site advertises a low “solar cable per metre” figure, check the conductor. Bare or plain copper, tinned copper and aluminium are different products. A two-core price is not the same as two separate single-core lengths. A house wire that happens to be sold per metre is not automatically suitable for the PV DC side. Compare the printed standard, voltage rating, UV and temperature properties, conductor area, manufacturer and part number. The RR Kabel product page describes its IS 17293 solar cable construction and use; the exact selected datasheet governs the project design.
Why the cable length in a quote often doubles
Most PV DC circuits need a positive and a negative conductor. If the physical route from array to inverter is 24 metres, the cable purchase is not automatically 24 metres. For a simple one-string path with separate single-core runs, the starting conductor length is approximately 24 m positive plus 24 m negative, or 48 conductor-metres. Add actual array interconnections, bends, routing around obstacles, terminations and design allowance. Then repeat for each independently routed string. Factory leads already attached to modules and prefabricated harnesses should be identified so they are neither omitted nor counted twice.
The word “route” matters. A straight-line roof-to-inverter distance may be 14 metres while the safe installed path uses a cable tray, conduit, parapet transition and service loop. A site survey should mark the actual route on a roof or electrical layout. Measure from the relevant string end or combiner, not from a convenient roof corner. On a commercial roof, two strings may share part of a tray but still each require their own positive and negative conductors unless the electrical design explicitly combines them earlier.
Use a simple schedule with columns for circuit, positive route, negative route, number of runs, connection allowance and total conductor-metres. If the positive and negative paths differ, record both. Count cable that moves from an array to a DC combiner separately from cable that runs from the combiner to the inverter. The designer should confirm whether the lengths also fit voltage-drop and safety limits. A cost spreadsheet cannot decide that on its own.
| Circuit segment | Positive conductor | Negative conductor | Other allowance | Purchased-length starting point |
|---|---|---|---|---|
| One string, 24 m measured route each way | 24 m | 24 m | 4 m joint routing/termination assumption | 52 conductor-metres |
| Two identical strings on separate 24 m routes | 48 m | 48 m | 8 m assumed total allowance | 104 conductor-metres |
| Shared tray after a combiner | Measure design | Measure design | Record separately | Do not infer from roof dimensions |
The allowances in this table are illustrative inputs, not a standard percentage or rule. The first row means two 24 m conductors plus 4 m total allowance, yielding 52 m of single-core cable. The second row doubles that example. Your site can need more or less depending on terminations, routing and delivered coil lengths. Use a measured design for a real customer.
Work a price example without disguising assumptions
Suppose a surveyed one-string route requires 52 conductor-metres of the specified 4 mm² RR Kabel single-core cable, using the illustrative length above. Multiplying 52 by the August 2026 list arithmetic of ₹153.17/m gives ₹7,964.84 as a purely mathematical cable-material reference. The same 52 m at the published 6 mm² arithmetic rate of ₹221.16/m gives ₹11,500.32. The difference, ₹3,535.48, shows why an unapproved size change can affect a small project's material allowance. It does not prove that 6 mm² is necessary or that 4 mm² is sufficient.
Neither product amount is a customer quote. The manufacturer list excludes GST; it gives standard packing terms; and a distributor may quote a different net rate or minimum length. Add the actual purchase quantity and supplier terms, then separately account for connectors, glands, ferrules where appropriate, DC isolator or combiner, conduit/tray, clamps, labels, testing and labour. If the job consumes 52 m but the seller charges for a 100 m coil, your cost basis changes unless the balance is genuinely reusable and accounted for in your inventory system. Do not quietly treat a coil as 52 m of purchased material.
A practical costing formula is:
Cable material cost before tax = purchased metres × supplier net price per metre, using a consistent product and purchase unit. Installed DC wiring price also includes supported route protection, terminations, testing, labour, freight/tax where applicable and an explicit commercial margin.
Keep the customer's line item readable. A residential buyer may not need every connector's unit cost in the proposal, but should be able to see the specified cable family and whether the DC wiring, route protection and installation are included. A commercial buyer or tender may require a bill of quantities with separate sizes, runs and rates. Adjust the document to the buyer's procurement process without hiding a material assumption.
Choose the size by design, then price it
A common pricing mistake is to pick the cheapest cross-section from a list and use it as the design. Cable size follows the maximum circuit current, current-carrying capacity in the installation method, voltage drop, short-circuit and protection conditions, ambient and grouping effects, mechanical route and the selected standard. A long hot rooftop run can behave differently from a short protected route. The inverter and module datasheets also constrain the electrical design. The designer should calculate and sign off the chosen size; procurement should then price that exact specification.
The RR Kabel solar cable datasheet page publishes different current-carrying figures for a single cable in free air, on a surface and for two loaded cables touching on a surface. That alone shows why a nominal “4 mm² handles X amps” sentence is incomplete. Installation method changes the rating. Do not transfer a manufacturer's figure to a different cable, different temperature or different installation without the relevant derating and engineering review.
Voltage drop needs its own calculation over the whole circuit. The module and inverter operating range, expected current, one-way path, conductor resistance and temperature matter. The relevant path can include both positive and negative conductors. A small-looking resistance per kilometre can become material over a long DC route, and the resistance changes with temperature. Quote the design decision and the resultant length; do not advertise a universal metre limit for 4 or 6 mm² cable.
Check the cable's exact print and certificate for the applicable Indian quality-control requirement. The RR Kabel product page cites the DC solar cable Quality Control Order and IS 17293 marking; the legal text and BIS licence for the selected item should be checked for the current project. Avoid claiming that every cable carrying an international standard is automatically accepted in India. The manufacturer's brochure, supplied coil label and invoice should agree on the cable family and size.
Break the wiring scope into measurable parts
A clean quote should distinguish PV DC cable from AC cable. The AC run from inverter to distribution board can have a different conductor size, core count, protection and pricing unit. Earthing conductors, lightning protection conductors, communication cable and cable trays are also distinct. Do not put all of them under “solar wire ₹X/m” and assume the customer understands what is included.
For a straightforward rooftop project, list the DC cable by manufacturer, product range, standard/voltage rating, conductor size, colour identification, total estimated conductor-metres and route scope. State whether the installed quantity will be measured for billing or the quote is a fixed sum based on a surveyed route. If the route is unconfirmed, give a provisional quantity with a written variation method. A fixed-price buyer deserves to know when a hidden route or utility-mandated change could alter the price.
For a larger project, prepare a cable schedule. It can include string ID, from/to point, one-way path, positive and negative lengths, size, voltage rating, installation method, tray/conduit route and connector type. This schedule helps procurement ask for a comparable supplier quote and helps the site crew install the design actually sold. It also makes later fault-finding easier, because the as-built circuit names can match the quotation and commissioning record.
| Quote line | What to write | What to avoid |
|---|---|---|
| DC cable specification | Exact brand/range or approved equivalent, tinned-copper single-core size and relevant standard | “Solar wire” without type or size |
| Quantity | Estimated purchased or installed conductor-metres, clearly labelled | One-way route metres passed off as both conductors |
| Commercial basis | Supplier quote date, GST and freight treatment, validity | Undated internet price described as current market rate |
| Route accessories | Connectors, conduit/tray and supports included or separately itemised | Cable-only rate presented as complete wiring price |
| Change condition | How extra route length or model substitution is approved | Open-ended “as actual” charge with no method |
The table is a customer-document checklist. It does not require every residential PDF to expose internal supplier discounts or margin. It does require the proposal to describe what is being sold and how a change will be handled.
Compare supplier offers on a common basis
Ask at least the questions that change an effective rate. Is the quotation per metre, per 100 m or per coil? Is the item single-core or twin-core? What is the exact conductor area and standard? Is GST included? Is freight included to the site or collection point? What is the minimum order? Are red and black or striped identification variants priced the same? Is the offered SKU currently in stock? What is the offer validity? A low headline rate can lose its advantage when purchase minimum and freight are included.
A landed-cost comparison is more useful than copying a single column from a price PDF. For each offer, calculate total payable for the required purchased quantity, excluding any recoverable tax only if your accounting treatment supports that comparison. Divide by usable purchased metres to compare effective material cost. Keep labour and route protection outside this supplier comparison so the result remains about cable. If coils leave a reusable balance, note it honestly rather than assuming full waste or full credit.
Check counterfeit and substitution risk at goods receipt. The coil label, manufacturer print, area, batch information and invoice should match the order. A supplied cable with a different material or construction may require redesign even if the nominal area is the same. Treat procurement acceptance as part of quality control, not a paperwork formality after installation.
Put the price in a proposal the buyer can understand
For a fixed-scope project, a concise line might read: “PV DC wiring: [selected manufacturer and range], 4 mm² single-core tinned-copper solar cable, positive and negative runs, approximately 52 conductor-metres on the surveyed route; cable protection, connectors, installation and testing included.” Fill the bracketed facts from the actual design and supplier offer. If a route is provisional, state the included length and a specific approved extra-rate method. Do not copy the illustrative 52 m from this article into a real job.
For a measured commercial job, separate cable supply, installation and accessories when the bill of quantities requires it. Name the price basis and validity. If the supplier quote expires before customer acceptance, refresh the rate before sending a final version. A versioned proposal protects the customer from a silent price or product change. Quickest Solar CRM can put selected items and terms into a branded PDF and share it through WhatsApp. The quotation-system feature supports the document workflow; the electrical design and supplier price still come from your team. Start free to inspect a proposal with your actual cable scope.
Quick answers
What is the 4 mm² solar DC cable price per metre? RR Kabel's dated August 2026 list gives ₹15,317 per 100 m, equivalent to ₹153.17/m before GST by division. That is one specified manufacturer's list rate, not a live retail quote or installed rate. Request a current offer for the exact product and purchase quantity.
Is 6 mm² always better than 4 mm²? A larger conductor may reduce resistance, but the correct size depends on circuit current, length, installation method and design constraints. Compare calculated performance and total installed cost. Do not upsize or downsize solely from a price table.
How many metres should I quote for a 20 m run? If that is a one-way route for one separate positive and negative pair, start with about 40 conductor-metres, then add measured connections and route allowance. The number of strings, combiner layout and factory leads can change the result.
Does the listed price include GST? The cited RR Kabel list states prices are exclusive of GST. Your supplier offer should state its own tax and freight terms. Do not assume the same treatment for another seller.
Can I use ordinary building wire on the DC side? Select a cable designed and accepted for the PV DC application, using the current product standard and project requirements. A house-wire price is not a sound substitute for a solar-cable quotation.
The reliable answer to “solar DC cable price per metre” is a dated, specified material rate paired with a measured conductor quantity and a current supplier offer. The manufacturer list can anchor your estimate; the approved design and purchase terms should determine the customer's final cable line.